Summary of Medical Biophysics: Principles and Practice

Medical Biophysics: Principles and Practice

Introduction

Measurements are the language of physics and engineering. This guide explains the International System of Units (SI), commonly used units accepted with the SI, how derived units are formed, and how to report uncertainties and handle measurement errors. It is written for a Not attending student and focuses on clear, practical understanding.

SI System of Units: Overview

The Système International d'Unités (SI) provides a consistent set of units for science and technology.

The SI system classifies units as base, derived, and prefixed units to ensure consistency and scalability.

Base, Derived and Prefixed Units

  • Base units: fundamental quantities like metre, kilogram, second, ampere, kelvin, mole, candela.
  • Derived units: combinations of base units, e.g., velocity, density, force, voltage.
  • Prefixed units: use prefixes (kilo-, milli-, micro-, etc.) to scale units by powers of ten.

Units Accepted for Use with the SI

Some non-SI units are officially accepted for use with the SI because they are convenient in practice. Key examples:

QuantitySymbolDefinition in SI units
minute (time)min$1\ \text{min} = 60\ \text{s}$
hourh$1\ \text{h} = 60\ \text{min} = 3600\ \text{s}$
dayd$1\ \text{d} = 24\ \text{h} = 86,400\ \text{s}$
degree (angle)$^{\circ}$$1^{\circ} = \frac{\pi}{180}\ \text{rad}$
minute (angle)$^{\prime}$$1^{\prime} = \frac{1}{60}^{\circ} = \frac{\pi}{10,800}\ \text{rad}$
second (angle)$^{\prime\prime}$$1^{\prime\prime} = \frac{1}{60}^{\prime} = \frac{\pi}{648,000}\ \text{rad}$
litreL, l$1\ \text{L} = 1\ \text{dm}^{3} = 10^{-3}\ \text{m}^{3}$
metric tont$1\ \text{t} = 10^{3}\ \text{kg}$
belB$1\ \text{B} = 10\ \text{dB}$ (commonly use dB)
electronvolteV$1\ \text{eV} = 1.602\times 10^{-19}\ \text{J}$
💡 Did you know?Did you know that the electronvolt is a convenient energy unit in atomic and particle physics because it corresponds to the energy gained by an electron accelerated through a potential difference of one volt?

Derived SI Units: Combinations and Dimensionless Units

Derived units are formed by algebraic combinations of base units.

Examples:

  • Area: $\text{m}^{2}$
  • Mass density: $\text{kg},\text{m}^{-3}$
  • Speed: $\text{m},\text{s}^{-1}$
  • Frequency: $\text{Hz} = \text{s}^{-1}$
  • Force: $\text{N} = \text{kg},\text{m},\text{s}^{-2}$
  • Voltage: $\text{V} = \text{kg},\text{m}^{2},\text{s}^{-3},\text{A}^{-1}$

Dimensionless derived units are used for angles and solid angles:

NameSymbolQuantity
radianradplane angle
steradiansrsolid angle
💡 Did you know?Fun fact: angles are dimensionless in SI because a radian is defined as the ratio of an arc length to a radius, so units cancel out.

Uncertainties of Measurement

All measurements have limited precision. Properly reporting a measurement includes the value, the unit, and the uncertainty.

The standard notation for a measured quantity is $x_{0} \pm \Delta x$, where $\Delta x$ is the absolute uncertainty.

Definitions:

  • Absolute uncertainty: $\Delta x$.
  • Relative (fractional) uncertainty: $\Delta_{r} x = \dfrac{\Delta x}{x_{0}}$.
  • Percentage uncertainty: $\Delta_{%} x = \dfrac{\Delta x}{x_{0}}\cdot 100%$.

How to estimate uncertainty

  • Manufacturer specification: use the stated instrument accuracy.
  • Reading analogue scales: estimate as half of the smallest division if no other information is available.
  • Repeat measurements: use statistical spread (see below) to reduce random errors.

When recording a measurement, always include the number, the unit, and the uncertainty, for example $5.00\ \text{m} \pm 0.02\ \text{m}$.

Sources of Measurement Errors

Errors reduce the accuracy of results. Distinguish between random and systematic errors.

Random errors

  • Caused by uncontrollable fluctuations such as small temperature changes, voltage
Sign up for the full summary
FlashcardsKnowledge testSummaryPodcastMindmap
Start for free

Already have an account? Sign in

Units and Measurement

Klíčová slova: Medical Biophysics, Units and Measurement, Data Types, Descriptive Statistics, Anthropometry

Klíčové pojmy: SI has base, derived, and prefixed units, Record measurements as value, unit, and uncertainty $x_{0} \pm \Delta x$, Absolute uncertainty $\Delta x$, relative $\Delta_{r} x = \dfrac{\Delta x}{x_{0}}$, Percentage uncertainty $\Delta_{\%} x = \dfrac{\Delta x}{x_{0}}\cdot 100\%$, Common non-SI units accepted: min, h, d, degree, L, t, eV, Derived units are combinations of base units, e.g. $\text{N} = \text{kg}\,\text{m}\,\text{s}^{-2}$, Random errors vary and reduce with repetition, Systematic errors shift results and require calibration to fix

## Introduction Measurements are the language of physics and engineering. This guide explains the International System of Units (SI), commonly used units accepted with the SI, how derived units are formed, and how to report uncertainties and handle measurement errors. It is written for a Not attending student and focuses on clear, practical understanding. ## SI System of Units: Overview The **Système International d'Unités (SI)** provides a consistent set of units for science and technology. > The SI system classifies units as **base**, **derived**, and **prefixed** units to ensure consistency and scalability. ### Base, Derived and Prefixed Units - **Base units**: fundamental quantities like metre, kilogram, second, ampere, kelvin, mole, candela. - **Derived units**: combinations of base units, e.g., velocity, density, force, voltage. - **Prefixed units**: use prefixes (kilo-, milli-, micro-, etc.) to scale units by powers of ten. ## Units Accepted for Use with the SI Some non-SI units are officially accepted for use with the SI because they are convenient in practice. Key examples: | Quantity | Symbol | Definition in SI units | | --- | ---: | --- | | minute (time) | min | $1\ \text{min} = 60\ \text{s}$ | | hour | h | $1\ \text{h} = 60\ \text{min} = 3600\ \text{s}$ | | day | d | $1\ \text{d} = 24\ \text{h} = 86\,400\ \text{s}$ | | degree (angle) | $^{\circ}$ | $1^{\circ} = \frac{\pi}{180}\ \text{rad}$ | | minute (angle) | $^{\prime}$ | $1^{\prime} = \frac{1}{60}^{\circ} = \frac{\pi}{10\,800}\ \text{rad}$ | | second (angle) | $^{\prime\prime}$ | $1^{\prime\prime} = \frac{1}{60}^{\prime} = \frac{\pi}{648\,000}\ \text{rad}$ | | litre | L, l | $1\ \text{L} = 1\ \text{dm}^{3} = 10^{-3}\ \text{m}^{3}$ | | metric ton | t | $1\ \text{t} = 10^{3}\ \text{kg}$ | | bel | B | $1\ \text{B} = 10\ \text{dB}$ (commonly use dB) | | electronvolt | eV | $1\ \text{eV} = 1.602\times 10^{-19}\ \text{J}$ | Did you know that the electronvolt is a convenient energy unit in atomic and particle physics because it corresponds to the energy gained by an electron accelerated through a potential difference of one volt? ## Derived SI Units: Combinations and Dimensionless Units Derived units are formed by algebraic combinations of base units. Examples: - Area: $\text{m}^{2}$ - Mass density: $\text{kg}\,\text{m}^{-3}$ - Speed: $\text{m}\,\text{s}^{-1}$ - Frequency: $\text{Hz} = \text{s}^{-1}$ - Force: $\text{N} = \text{kg}\,\text{m}\,\text{s}^{-2}$ - Voltage: $\text{V} = \text{kg}\,\text{m}^{2}\,\text{s}^{-3}\,\text{A}^{-1}$ Dimensionless derived units are used for angles and solid angles: | Name | Symbol | Quantity | | --- | ---: | --- | | radian | rad | plane angle | | steradian | sr | solid angle | Fun fact: angles are dimensionless in SI because a radian is defined as the ratio of an arc length to a radius, so units cancel out. ## Uncertainties of Measurement All measurements have limited precision. Properly reporting a measurement includes the value, the unit, and the uncertainty. > The standard notation for a measured quantity is $x_{0} \pm \Delta x$, where $\Delta x$ is the absolute uncertainty. Definitions: - Absolute uncertainty: $\Delta x$. - Relative (fractional) uncertainty: $\Delta_{r} x = \dfrac{\Delta x}{x_{0}}$. - Percentage uncertainty: $\Delta_{\%} x = \dfrac{\Delta x}{x_{0}}\cdot 100\%$. ### How to estimate uncertainty - Manufacturer specification: use the stated instrument accuracy. - Reading analogue scales: estimate as half of the smallest division if no other information is available. - Repeat measurements: use statistical spread (see below) to reduce random errors. > When recording a measurement, always include the number, the unit, and the uncertainty, for example $5.00\ \text{m} \pm 0.02\ \text{m}$. ## Sources of Measurement Errors Errors reduce the accuracy of results. Distinguish between random and systematic errors. ### Random errors - Caused by uncontrollable fluctuations such as small temperature changes, voltage