Summary of Medical Biophysics: Principles and Practice
Medical Biophysics: Principles and Practice
Introduction
Measurements are the language of physics and engineering. This guide explains the International System of Units (SI), commonly used units accepted with the SI, how derived units are formed, and how to report uncertainties and handle measurement errors. It is written for a Not attending student and focuses on clear, practical understanding.
SI System of Units: Overview
The Système International d'Unités (SI) provides a consistent set of units for science and technology.
The SI system classifies units as base, derived, and prefixed units to ensure consistency and scalability.
Base, Derived and Prefixed Units
- Base units: fundamental quantities like metre, kilogram, second, ampere, kelvin, mole, candela.
- Derived units: combinations of base units, e.g., velocity, density, force, voltage.
- Prefixed units: use prefixes (kilo-, milli-, micro-, etc.) to scale units by powers of ten.
Units Accepted for Use with the SI
Some non-SI units are officially accepted for use with the SI because they are convenient in practice. Key examples:
| Quantity | Symbol | Definition in SI units |
|---|---|---|
| minute (time) | min | $1\ \text{min} = 60\ \text{s}$ |
| hour | h | $1\ \text{h} = 60\ \text{min} = 3600\ \text{s}$ |
| day | d | $1\ \text{d} = 24\ \text{h} = 86,400\ \text{s}$ |
| degree (angle) | $^{\circ}$ | $1^{\circ} = \frac{\pi}{180}\ \text{rad}$ |
| minute (angle) | $^{\prime}$ | $1^{\prime} = \frac{1}{60}^{\circ} = \frac{\pi}{10,800}\ \text{rad}$ |
| second (angle) | $^{\prime\prime}$ | $1^{\prime\prime} = \frac{1}{60}^{\prime} = \frac{\pi}{648,000}\ \text{rad}$ |
| litre | L, l | $1\ \text{L} = 1\ \text{dm}^{3} = 10^{-3}\ \text{m}^{3}$ |
| metric ton | t | $1\ \text{t} = 10^{3}\ \text{kg}$ |
| bel | B | $1\ \text{B} = 10\ \text{dB}$ (commonly use dB) |
| electronvolt | eV | $1\ \text{eV} = 1.602\times 10^{-19}\ \text{J}$ |
Derived SI Units: Combinations and Dimensionless Units
Derived units are formed by algebraic combinations of base units.
Examples:
- Area: $\text{m}^{2}$
- Mass density: $\text{kg},\text{m}^{-3}$
- Speed: $\text{m},\text{s}^{-1}$
- Frequency: $\text{Hz} = \text{s}^{-1}$
- Force: $\text{N} = \text{kg},\text{m},\text{s}^{-2}$
- Voltage: $\text{V} = \text{kg},\text{m}^{2},\text{s}^{-3},\text{A}^{-1}$
Dimensionless derived units are used for angles and solid angles:
| Name | Symbol | Quantity |
|---|---|---|
| radian | rad | plane angle |
| steradian | sr | solid angle |
Uncertainties of Measurement
All measurements have limited precision. Properly reporting a measurement includes the value, the unit, and the uncertainty.
The standard notation for a measured quantity is $x_{0} \pm \Delta x$, where $\Delta x$ is the absolute uncertainty.
Definitions:
- Absolute uncertainty: $\Delta x$.
- Relative (fractional) uncertainty: $\Delta_{r} x = \dfrac{\Delta x}{x_{0}}$.
- Percentage uncertainty: $\Delta_{%} x = \dfrac{\Delta x}{x_{0}}\cdot 100%$.
How to estimate uncertainty
- Manufacturer specification: use the stated instrument accuracy.
- Reading analogue scales: estimate as half of the smallest division if no other information is available.
- Repeat measurements: use statistical spread (see below) to reduce random errors.
When recording a measurement, always include the number, the unit, and the uncertainty, for example $5.00\ \text{m} \pm 0.02\ \text{m}$.
Sources of Measurement Errors
Errors reduce the accuracy of results. Distinguish between random and systematic errors.
Random errors
- Caused by uncontrollable fluctuations such as small temperature changes, voltage
Already have an account? Sign in
Units and Measurement
Klíčová slova: Medical Biophysics, Units and Measurement, Data Types, Descriptive Statistics, Anthropometry
Klíčové pojmy: SI has base, derived, and prefixed units, Record measurements as value, unit, and uncertainty $x_{0} \pm \Delta x$, Absolute uncertainty $\Delta x$, relative $\Delta_{r} x = \dfrac{\Delta x}{x_{0}}$, Percentage uncertainty $\Delta_{\%} x = \dfrac{\Delta x}{x_{0}}\cdot 100\%$, Common non-SI units accepted: min, h, d, degree, L, t, eV, Derived units are combinations of base units, e.g. $\text{N} = \text{kg}\,\text{m}\,\text{s}^{-2}$, Random errors vary and reduce with repetition, Systematic errors shift results and require calibration to fix