Summary of Medical Biophysics: Mechanical and Acoustic Factors
Medical Biophysics: Mechanical and Acoustic Factors
Introduction
Understanding units and measurement is essential for all areas of physics and engineering. This guide explains the International System of Units (SI), commonly used non-SI units accepted with the SI, how derived units form from base units, and how to treat uncertainties and measurement errors. Clear definitions, practical examples, and concise rules will help you study independently.
Definition: The SI (Système International d'Unités) is the modern form of the metric system and provides standardized base units, derived units, and prefixes for expressing quantities consistently.
The SI system: overview
- The SI contains base units (e.g., metre, kilogram, second), derived units (formed from base units), and prefixed units (using powers of ten).
- Using SI ensures consistent communication of measurements worldwide.
Base and derived units
- Base units are the fundamental building blocks, e.g., metre ($\mathrm{m}$), kilogram ($\mathrm{kg}$), second ($\mathrm{s}$), ampere ($\mathrm{A}$), kelvin ($\mathrm{K}$), mole ($\mathrm{mol}$), candela ($\mathrm{cd}$).
- Derived units are combinations of base units, often with special names:
| Quantity | Derived unit | Relationship to base units |
|---|---|---|
| Area | square metre ($\mathrm{m^2}$) | $\mathrm{m^2}$ |
| Density | kilogram per cubic metre ($\mathrm{kg,m^{-3}}$) | $\mathrm{kg,m^{-3}}$ |
| Speed | metre per second ($\mathrm{m,s^{-1}}$) | $\mathrm{m,s^{-1}}$ |
| Frequency | hertz (Hz) | $\mathrm{s^{-1}}$ |
| Force | newton (N) | $\mathrm{kg,m,s^{-2}}$ |
| Voltage | volt (V) | $\mathrm{kg,m^2,s^{-3},A^{-1}}$ |
Definition: A derived unit is any unit expressible in terms of the base units of the SI.
Dimensionless derived units
| Name | Symbol | Use |
|---|---|---|
| Radian | rad | plane angle, dimensionless ($$\text{angle (rad)}=\frac{\text{arc length}}{\text{radius}}$$) |
| Steradian | sr | solid angle |
Chosen non-SI units accepted for use with the SI
Some non-SI units are widely used and officially accepted with the SI. Common ones include:
| Unit | Symbol | Relation to SI |
|---|---|---|
| minute (time) | min | $1\ \text{min} = 60\ \mathrm{s}$ |
| hour | h | $1\ \mathrm{h} = 60\ \mathrm{min} = 3600\ \mathrm{s}$ |
| day | d | $1\ \mathrm{d} = 24\ \mathrm{h} = 86400\ \mathrm{s}$ |
| degree (angle) | $^\circ$ | $1^\circ = \frac{\pi}{180}\ \mathrm{rad}$ |
| minute (angle) | $'$ | $1' = \frac{1}{60}^\circ = \frac{\pi}{10800}\ \mathrm{rad}$ |
| second (angle) | $''$ | $1'' = \frac{1}{60}' = \frac{\pi}{648000}\ \mathrm{rad}$ |
| litre | L, l | $1\ \mathrm{L} = 1\ \mathrm{dm^3} = 10^{-3}\ \mathrm{m^3}$ |
| metric ton | t | $1\ \mathrm{t} = 10^{3}\ \mathrm{kg}$ |
| bel | B | $1\ \mathrm{B} = 10\ \mathrm{dB}$ (decibel more commonly used) |
| electronvolt | eV | $1\ \mathrm{eV} = 1.602\cdot 10^{-19}\ \mathrm{J}$ |
Uncertainties of measurement
Definition: Measurement uncertainty quantifies the range within which the true value of a measured quantity is estimated to lie.
- Report a complete measurement as: $x_0 \pm \Delta x$, where $x_0$ is the measured value and $\Delta x$ is the absolute uncertainty.
- Absolute uncertainty: $\Delta x$.
- Relative (fractional) uncertainty: $\Delta_r x = \dfrac{\Delta x}{x_0}$.
- Percentage uncertainty: $\Delta% x = \dfrac{\Delta x}{x_0}\cdot 100%$.
Practical rules for estimating uncertainty
- Use manufacturer specifications for instrument accuracy when available.
- If reading a simple scale, estimate the uncertainty as half of the smallest division.
Example: A ruler with millimetre markings used to measure a length $L = 123\ \mathrm{mm}$, uncertainty estimate $\Delta L \approx 0.5\ \mathrm{mm}$, so report $L = 123.0\pm 0.5\ \mathrm{mm}$.
Already have an account? Sign in
Units and Measurement
Klíčová slova: Medical Biophysics Education, Units and Measurement, Data and Statistics, Anthropometry
Klíčové pojmy: SI includes base, derived, and prefixed units, Report measurements as $x_0 \pm \Delta x$ with unit, Absolute uncertainty $\Delta x$, relative $\Delta_r x = \Delta x / x_0$, Use manufacturer specs or half smallest division to estimate instrument uncertainty, Common non-SI units accepted: min, h, d, degree, litre, t, eV, Derived units expressed in base units, e.g. N = $\mathrm{kg\,m\,s^{-2}}$, Random errors reduced by repeating measurements, Systematic errors require calibration or method correction